MIK-DO700 Optical dissolved oxygen meter

Short Description:

MIK-DO700 dissolved Oxygen meter adopts fluorescence method to measure dissolved oxygen.The cap of the sensor is coated with a luminescent material. Blue light from an LED illuminates the luminescent chemical. The luminescent chemical instantly becomes excited and releases red light. The time and intensity of red light are inversely proportional to the concentration of oxygen molecules, So the concentration of oxygen molecules is calculated. Features Range: 0-20mg/L,0-200%,0-400hPaResolution:0.01mg/L,0.1%,1hPaOutput signal: 4~20mA; Relay; RS485Power supply: AC220V±10%; 50Hz/60Hz


Product Detail

Product Tags

  • Specification
  Product Dissolved oxygen meter
  Model SUP-DO700
  Measure range 0-20mg/L,0-20ppm,0-45deg C
  Accuracy Resolution:±3%, Temperature: ±0.5℃
  Pressure range ≤0.3Mpa
  Calibration Automatic air calibration,Sample calibration
  Sensor material SUS316L+PVC (Ordinary Version),
Titanium Alloy (Seawater Version)
O-ring: Fluoro-rubber; Cable: PVC
  Cable length Standard 10-Meter Cable, Max : 100m
  Display 128 * 64 dot matrix LCD with LED backlight
  Output 4-20mA(Max three-way);
RS485 MODBUS;
Rlay output(Max three-way);
  Power supply AC220V, 50Hz,(optional 24V)

 

  • Introduction

SUP-DO700 Dissolved oxygen meter measures the dissolved oxygen by the fluorescence method, and the emitted blue light is irradiated on the phosphor layer. The fluorescent substance is stimulated to emit red light, and the oxygen concentration is inversely proportional to the time when the fluorescent substance returns to the ground state. By using this method to measure the dissolved oxygen, it will not produce oxygen consumption, thus assuring data stability, reliable performance, no interference, and simple installation and calibration.

 

  • Application

 

  • Product Advantages

Ø The sensor adopts new type of oxygen sensitive membrane,with NTC temperature compensated function,whose measurement result has good repeatability and stability.

Ø Won’t produce oxygen consumption when measuring and no requirement of flow rate and stirring.

Ø Breakthrough fluorescence technology,without membrane and the electrolyte and almost not need maintenance.

Ø Built-in self-diagnosis function to ensure the accuracy of data.

Ø Factory calibration,not need calibration for a year and can carry out field calibration.

Digital sensor,high anti-jamming capacity and far transmission distance.

Standard digital signal output,can achieve integration and networking with other equipment without controller.

Ø Plug-and-play sensor,quick and easy installation.

Industrial controlled door keep, to avoid instrument halted.


  • Previous:
  • Next:

  • Write your message here and send it to us
    TOP